www.gdsys.de
// DC 12
7.0
DVICenter DP32
Expansions
Central module expansion: Cascading
The DVICenter DP32 system can be cascaded in three levels
to increase the number of connectable computers. The master
carries out all control tasks. The examples as shown assure full
access for all consoles to all computers in all cascade levels.
Cascading adds an additional transmission distance of 140 m
per DVICenter DP32. Therefore, the distance from the computer
to the cascaded central modules through to the user module can
be up to 560 m at the highest cascade level.
Possible number of computers in full-matrix cascading
Stand alone slave 1 / cascade level 1 slave 2 / cascade level 2
no. of user ports computer ports no. of computers no. of DVICenter no. of computers no. of DVICenter
1 31 961 32 - -
2 30 450 16 6 750 241
3 29 263 10 2 369 91
4 28 196 8 1 372 57
5 27 137 6 687 31
6 26 106 5 426 21
7 25 79 4 241 13
8 24 72 4 216 13
9 23 51 3 107 7
10 22 46 3 94 7
11 21 31 2 41 3
12 20 28 2 36 3
13 19 25 2 31 3
14 18 22 2 26 3
15 17 19 2 21 3
16 16 - - - -
Computer
module
DVI-CPU-UC
Item no.
A232 0052
rear view DVI-CPU-UC
Expansion of number of users
By applying the computer module DVI-CPU-UC or DVI-CPU-UC-
Wintu3, two DVICenter clusters can access one computer.
The number of accesses can be doubled thereby.
The UC modules are directly connected to a power source.
Technical data DVI-CPU-UC
Signal type/video DVI-D single-link
Video resolution 1920 x 1200 @ 60 Hz
Colour depth 24 bit
Audio Resolution 24 bit digital
Sampling rate 96 kHz
Bandwidth 22 kHz
Interfaces to central module 2
Transmission length 140 m
computer module to central module
Transmission type to central module dedicated
CAT-x link
Power supply Main Type external power pack
Connection Mini-DIN 4 socket
Voltage +12V DC/700mA
Casing Material anodised aluminium
Dimensions (W x H x D) 105 x 26 x 124 mm
Build converter
Weight approx. 0.24 kg
Interfaces to computer video DVI-D socket
PS/2
keyb./mouse 2 x Mini-DIN 6 socket
USB keyb /mouse USB-B socket
audio 2 x 3,5 mm jack plug
for updates Mini-USB-B socket
to central module 2 x RJ45 socket
Conformity CE, RoHS
x = 5e, 6, 7