xStack
®
DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch
26
Connect to RPS
The DPS-200 is connected to the Master Switch using a 14-pin DC power cable. A standard, three-pronged AC power cable
connects the redundant power supply to the main power source.
Figure 2- 17. Connecting the DGS-3200-24 to the DPS-200
1. Insert one end of the 14-pin DC power cable into the receptacle on the switch and the other end into the redundant power
supply.
2. Using a standard AC power cable, connect the redundant power supply to th e main AC power source. A green LED on
the front of the DPS-200 will glow to indicate a successful connection.
3. Re-connect the switch to th e AC power source. The n LED ind icator will show that a red undant power supply is now in
operation.
4. No change in switch configuration is necessary for this installation.
NOTE: See the DPS-200 documentation for more information.
CAUTION: Do not use the DGS-3200-24 with any redundant power
system other than the DPS-200.