Figure 8- 15. Login Method List Settings window
The Switch contains one Method List that is set and cannot be removed, yet can be modified. To delete a Login Method List
defined by the user, click the
under the Delete heading corresponding to the entry desired to be deleted. To modify a
Login Method List, click on its hyperlinked Method List Name. To configure a new Method List, click the Add button.
Both actions will result in the same screen to configure:
Figure 8- 16. Login Method List - Edit window (default)
Figure 8- 17. Login Method List – Add window
To define a Login Method List, set the following parameters and click Apply:
Parameter Description
Method List Name
Enter a method list name defined by the user of up to 15 characters.
Method 1, 2, 3, 4
The user may add one, or a combination of up to four of the following authentication