D-Link DE-816TAC - Hub - Stackable Guía de usuario Pagina 115

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 147
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 114
Web-Based Network Management 103
Delete
Click the
Delete
button to remove an entry.
Following are descriptions for the categories shown in the Alarm Table:
Owner
The entity that configured the entry and is therefore using the
resources assigned to it.
Index
An index uniquely identifying an entry in the alarm table. Each
such entry defines a diagnostic sample at a particular interval.
Interval
The interval in seconds over which the data is sampled and
compared with the rising and falling thresholds. When setting this vari-
able, care should be taken in the case of Delta sampling – the interval
should be set short enough that the sampled variable is very unlikely to
increase or decrease by more than 2^31
1 during a single sampling in-
terval.
Variable
The object identifier of the particular variable to be sampled.
Sample Type
The method of sampling the selected variable and cal-
culating the value to be compared against the thresholds. If the value of
this object is
Absolute
, the value of the selected variable will be com-
pared directly with the thresholds at the end of the sampling interval. If
the value of this object is
Delta
, the value of the selected variable at the
last sample will be subtracted from the current value, and the difference
compared with the thresholds.