DES-7200 Hardware Installation Guide
1-9
The slots for the two management modules are in the middle, and they are identified as M1
and M2 from left to right. The other eight module line cards are numbered as 1-8 from the left
to the right.
When in full configuration, the modules in the module slots of the DES-7206 are as below:
Two management modules serving as mutual backup
Four modules selected to meet the specific needs
The slots for the two management modules are in the middle, and they are identified as M1
and M2 from bottom up. The other four module line cards are numbered as 1-4 from bottom
up.
1.5 Ventilation/Heat Dissipation
System of the DES-7206/7210
The oper ating t emperature of t he DES-7206/7210 is 0 -40°C. T he t hermal de sign m ust
ensure t hat t he s urface t emperature of t he c omponents do es n ot exceed the m aximum
allowed temperature of 50-80% at such an ambient temperature, while allowing for reliability,
security, and reparability. In the thermal design of the DES-7206/7210, the fans are used to
induct air for a forced convection in order to ensure the normal running of the equipment in
the specified environment. Figure 1-3 and Figure 1-4 show the ventilation/heat dissipation
solution.
Figure 1-3 Ventilation/Heat Dissipation Solution of the DES-7210
Note
This structure is designed with air inlet at front/back and two sides, and air
outlet at top back and both sides. Six 120*120*38 fans are used to blow
the air to the outside for convection and ultimately heat dissipation.
Therefore, the chassis should be mounted at a place with adequate
spacing around for air circulation.