102 Chapter 5 Configuring the XStack Storage
5.3.7 Changing the iSCSI Port Number
The iSCSI port number is the TCP/IP port number on which the iSCSI target is listening. The
standard port number for iSCSI is 3260, but some targets may allow the port number to be
customized. To change the iSCSI port number, use the following procedure.
1. Click the XStack Storage icon at the top of the Physical Resources tab.
2. Perform one of the following steps:
On the File menu, click Change iSCSI Port Number.
Right-click and click Change iSCSI Port Number.
Either step displays the Modify iSCSI Port dialog box, with the current iSCSI port number
shown (see
Figure 5-39).
Figure 5-39. Modify iSCSI Port Dialog Box
2. Enter a new value for the iSCSI port.
3. Click OK.