DGS-3200 Series Layer 2 Managed Gigabit Ethernet Switch Web UI Reference Guide
78
Parameter Description
MLD Snooping State
Click the radio button to enable or disable the MLD snooping state.
Max Learned Entry Value (1-
256)
Specify the maximum number of groups that can be learned by the data driven
mechanism.
VID
This is the VLAN ID that, along with the VLAN Name, identifies the VLAN for which
to modify the MLD Snooping Settings.
VLAN Name
This is the VLAN Name that, along with the VLAN ID, identifies the VLAN for which
to modify the MLD Snooping Settings.
State
Used to enable or disable MLD snooping for the specified VLAN. This field is
Disabled by default.
Click Apply to implement changes made. Click the Edit button to configure the MLD Snooping Parameters Settings.
Click the Modify Router Port link to configure the MLD Snooping Router Port Settings.
Click the Edit button to see the following window:
Figure 3 - 38. MLD Snooping Parameters Settings window
The following parameters can be configured:
Parameter Description
Query Interval (1-65535 sec)
This parameter is used to specify the amount of time in seconds between general
query transmissions. Default: 125 seconds.
Max Response Time (1-25
sec)
This parameter is used to specify the maximum amount of time in seconds to wait for
reports from listeners. Default: 10 seconds.
Robustness Variable (1-7)
This parameter is used to provide fine-tuning that allows for expected packet losses
on a subnet. The value of the robustness variable is used in calculating the following
MLD message intervals:
Group listener intervalAmount of time that must pass before a multicast
router decides there are no more listeners of a group on a network. This
interval is calculated as follows: (robustness variable * query interval) + (1 *
query response interval).
Other querier present intervalAmount of time that must pass before a
multicast router decides that there is no longer another multicast router that
is the querier. This interval is calculated as follows: (robustness variable *
query interval) + (0.5 * query response interval).
Last listener query countNumber of group-specific queries sent before the
router assumes there are no local listeners of a group. The default number is
the value of the robustness variable.
By default, the robustness variable is set to 2. You might want to increase
this value if you expect a subnet to lose a high number of packets.