28
PRESSURE VARIABLES
VARIABLE DELTA0 - DELTA15
VALID VALUES -32768 to 32767
DEFAULT VALUE none
DATA TYPE integer
DESCRIPTION Delta zero corrections for channels 1 - 16. These values are set when a
CALZ is executed.
VARIABLE TEMPB0 - TEMPB15
VALID VALUES any real number
DEFAULT VALUE none
DATA TYPE float
DESCRIPTION The “B” term in the conversion equation used to convert temperature counts
to degrees Celsius. The conversion formula is:
VARIABLE TEMPM0 - TEMPM15
VALID VALUES any real number
DEFAULT VALUE none
DATA TYPE float
DESCRIPTION The “M” term in the conversion equation used to convert temperature counts
to degrees Celsius. The conversion formula is:
VARIABLE ZERO0 - ZERO15
VALID VALUES -32768 to 32767
DEFAULT VALUE none
DATA TYPE integer
DESCRIPTION The zero correction for channels 0 - 15. These values are set during the
original calibration and fill.
Comentarios a estos manuales